VT0009 : The Unrealistic Reality

Abstract

Purpos
One of the case histories, innovation, and surgery presented as video format
To evaluate the cost, safety, surgical outcome and efficacy of cutler beard eyelid reconstruction utilizing a novel silicone plate for tarsal plate replacement in the repair of 70-100% eyelid defects. Methods
Prospective, interventional case study of thirty patients over a period of eighteen months.Silicone plate obtained from a commercially available 279 scleral buckle was utilized.The created defect measured in percentage Pre and post-operative measurement of margin to reflex distance (MRD1)
Results
The follow-up period ranged from six months to two years. Pre-operative margin-to-reflex distanced (MRD1) ranged from -4 mm to -1 mm, while post-operative MRD1 was +3 to +4 mm.
Conclusions
The silicone is an inert, non-reacting, tissue tested material, thus eliminating the possibility of graft rejection.Silicone plate should be considered as a material of choice for tarsal plate replacement.