FP2542 : COMPARISON OF MESOPIC VISUAL ACUITY,CONTRAST SENSITIVITY AND GLARE ACUITY BETWEEN PDEK AND OPK

Abstract

STUDY DESIGN-Prospective observational study. PURPOSE-To compare mesopic visual acuity, contrast sensitivity and glare acuity between PDEK and OPK. METHODS-Patients who come for review any time between 6 months to 1 year following keratoplasty are identified.Visual acuity in mesopic luminance with glare on(4m) and glare off mode at a distance of 4m, intermediate 66cm and near 40cm is assessed along with contrast sensitivity at 4m of spatial frequencies of 1.5,3,6,12 cpd using Clinical Trial Suite software. RESULTS: Visual acuity after PDEK(0.56+/-0.3,p<0.03) was statistically significant than OPK. Mesopic contrast sensitivity at intermediate spatial frequencies(6cpd and 3cpd)(log (-1.65 + 0.39) (-1.77 + 0.32),p<0.02) was better in PDEK compared to OPK. CONCLUSION-Uncorrected Visual acuity was significantly better after PDEK compared to OPK and mesopic contrast sensitivity at intermediate spatial frequencies(3cpd and 6cpd) was better in PDEK compared to OPK.

Scroll to Top